Station timing: 0 min to 96 hrs
Program level and global Monthly Seasonal Adjust; 0% to 300% (96 hrs maximum station run time)
8 start times per program
Program Day Cycles include Custom days of the week, Odd, Odd no 31st, Even, and Cyclical dates
Manual station, program, test program
Diagnostic Features:
2-Wire Mapping: Maps the devices to corresponding wire paths in the controller to help quickly find and resolve issues
Self-Healing: Automatically detect “fixes” to wire path and splice issues and re-start irrigation without reliance on manual intervention
Two- Way Communication: with Intelligent Valve Modules (IVM) communication happens both ways enabling key features
Self-Shutoff : Once loss of power is detected, automatically shutoff valve to avoid leaks
Alarm light with external case lens
2-Wire diagnostics to simplify and expedite troubleshooting
Four isolated wire paths prevent full system failure under a single short
Trending 12-month electrical history reports and proactive action
Certifications:
cULus, CE, IPX4, UL, CUL, CSA, C-Tick, FCC Part 15
Environmental:
Operating temperature range: 14ºF to 149ºF (-10ºC to 65ºC)
Operating humidity range: 95% max at 40ºF to 120ºF (4ºC to 49ºC) in a non-condensing environment
Storage temperature range: -40ºF to 150ºF (-40ºC to 66ºC)
Optional Upgrade: IQ-NCC Network Communication Cartridge
Optional Upgrade: LXIVM Pro Panels (for regular 60 station controllers)
Electrical Specifications:
Power Supply Voltage: 120 VAC ± 10%, 60Hz
Power back-up: Lithium coin-cell battery maintains time and date while nonvolatile memory maintains the schedule
Simultaneous operation of up to eight (IVM) or sixteen (IVM Pro) Stations plus any corresponding master valves
|